EZ1029sc Nitrate Colorimetric Analyser, 1 stream, 4x mA Output

EZ1029sc Nitrate Colorimetric Analyser, 1 stream, 4x mA Output
Productnr.: EZ1029.9850140T
Prijs per eenheid Neem contact op

Trusted Equipment for Critical Operations

The EZ sc Series combines robust engineering with high-quality materials to ensure reliability 24/7. Designed for long-term performance, EZ sc Series minimises breakdowns and supports sustained operational success.

Scalable Solutions for Growing Needs

Built to evolve alongside your needs, online analysers from the EZ sc Series offer adaptable parameters and easier integration. They ensure your facility remains future proof without requiring expensive upgrades. Easily adjust parameter testing ranges and expand sample streams to accommodate innovation and growth.

Real-Time Data for Faster Decisions

The EZ sc Series offers advanced connectivity and real-time monitoring, delivering immediate access to actionable insights. Facilities utilising this technology benefit from improved reaction times, empowering more informed decision-making and quicker responses during critical situations.

Simplified Troubleshooting with Expert Support

Built-in diagnostics combined with secure remote data access make the EZ sc Series simplify issue resolution. Supported by a highly responsive team of experts, it ensures uninterrupted functionality and minimises operational downtime. By addressing and identifying issues early, EZ sc Series of online analysers helps prevent costly disruptions and repairs while maintaining system efficiency.

Clear Workflows for Predictable Outcomes

Standardised tools and guided workflows ensure consistent implementation and operation. The EZ sc Series minimises miscommunication, sets clear expectations, and reduces process inconsistencies, driving greater efficiency.

Wat zit er in de doos

EZ1029 Nitrate Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x empty 2.5L Reagent Container with Fittings (for Sulfamic Acid & Buffer Solution), 1 x empty 5L Reagent Container with Fittings (for Reductor Solution) and 1 x empty 2.5L Glass Reagent Container with Fittings (for Colour Solution)

Specificaties

Aantal monsterstromen: Standard: 1
Optional accessory for 2, 4, or 8 sample streams
Aardeaansluiting: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Afmetingen (H x B x D): 688 mm x 460 mm x 340 mm
Afvoerslang: Atmospheric pressure, vented, min. Ø 32 mm
Analoge uitgang: Active 0 - 20 mA (or 4 - 20 mA) max. 500 Ohm load, standard: 4, optional: 8
Automatische reiniging: Yes; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Beschermingsklasse: IP44
Certificering: CE, ETL certified to UL and CSA safety standards, UKCA
Cyclustijd: Default: 20 min.
Continuous: 16 min.
Demineralised water: Internal dilution option: Rinse water & Dilution water
Detectiegrens: 0.2 - 10 mg/L NO₃-N: 0.2 mg/L
Digital outputs: Profibus DP or Modbus RTU
Garantie: 24 maanden
Gewicht : Max. 35 kg
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar
Interferenties: Ions, e.g., antimony (III) (Sb3+), bismuth (III) (Bi3+), chloroplatinate (PtCl62–), gold (III) (Au3+), iron(III) (Fe3+), lead (II) (Pb2+), mercury (II) (Hg2+), metavanadate (VO3–) and silver (I) (Ag+) can cause precipitation with nitrate. Copper (Cu2+) ions can decompose the diazonium salt cause a low result. NCl3 can cause a red color. Strong oxidizing agents interfere. Large quantities of color and turbidity interfere. Fats, oil, proteins, surfactants and tar interfere.
Kalibratie: Automatic; 2-point; offset or slope; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced
Materiaal: Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Meetbereik: Internal Dilution
0.2 - 10 mg/L NO₃-N
Meetmethode: NEDD colorimetric method after reduction with hydrazine
Monster druk: By external overflow vessel (open to atmospheric pressure)
Monster kwaliteit: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Monster stroomsnelheid: 100 - 300 mL/min
Monster temperatuur: 10 - 30 °C
Omgevingstemperatuur: 10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Parameter: Nitrate
Precisie: Better than 2% full scale range for standard test solutions
Reagent Requirements: Keep Reducting reagent and Color Reagent refrigerated: 10 - 15 °C; all other between 10 - 30 °C
Relais: 5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150)
Stroom: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Uitgang: Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP
Validation: Automatic; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Wat zit er in de doos: EZ1029 Nitrate Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x empty 2.5L Reagent Container with Fittings (for Sulfamic Acid & Buffer Solution), 1 x empty 5L Reagent Container with Fittings (for Reductor Solution) and 1 x empty 2.5L Glass Reagent Container with Fittings (for Colour Solution)