Chloordosering onder controle

The CLF10 sc and CLT10 sc Chlorine Analysers are designed to be used with all Hach digital SC controllers. Set up is fast and easy, and the system is compatible with the full line of Hach digital sensors.

Minimale kosten

Chlorine measurement with the CLF10 sc and CLT10 sc amperometric technology eliminates the need for routine reagent replacement and waste stream management.

EPA Compliance

The CLF10 sc and CLT10 sc analysers can be used for reporting chlorine residual measurements in accordance with EPA Method 334.0. Additionally, Hach has created a suite of laboratory products and methods to help with startup and quality control procedures required for Method 334.0.

Real-time procescontrole

CLF10 sc and CLT10 sc advanced diagnostics alert you when the process has changed or the instument needs servicing. Diagnostic features include the Cal Watch algorithm for warning of pH and chlorine calibration deviation and a non-contacting sample flow sensor for notification of insufficient sample flow.

Real-time Process Monitoring and Control

The CLF10 sc and CLT10 sc Chlorine Analysers allow for real-time monitoring and control of disinfection processes.

Wat zit er in de doos

CL10sc Panel with Grab Sample, 1 m Digital Extension Cable, Panel Manual, Chlorine Sensor Manual

Specificaties

Aansluiting: ¼" OD
  ½" ID
Afmetingen: Sensor Only: 195 mm x 25 mm (7.68 in x 0.98 in)
Bevestingsstijl: Panel or Wall Mounting
Breedte: 495.3 mm
Certificering: CE compliant for conducted and radiated emissions:
- CISPR 11 (Class A limits)
- EMC Immunity EN 61326-1 (Industrial limits)
Additional certifications when connected to an sc controller
Controller: Panel only
Controller compatibiliteit: SC200, SC1000, SC4500. All controllers sold separately
Detectiegrens: 30 ppb (0.03 ppm)
Druk bereik: 0.5 bar, no pressure impulses and/or vibrations
Garantie: 24 maanden
Gewicht : Approximately 5.5 kg
Panel and empty panel-mounted components only
Herhaalbaarheid: 30 ppb or 3%, whichever is greater
Interferenties: Vrij chloor: monochlooramine, chloordioxide, ozon en kalkresten. Totaal chloor: chloordioxide, ozon en kalkresten
Kabel aansluiting : 5 pin, M12 connector
Kabel lengte: 1 m (between gateway and SC controller)
Kalibratie methode: 1-point or 2-point (zero and slope) calibration
Lengte : Sensor: 195 mm
Materiaal: Panel: Corrosion-resistant, fully-submersible (stainless steel, PVC, silicon rubber and polycarbonate)
Meetbereik: 0 - 20 ppm Cl₂
Meetmethode: Reagentless, electrochemical, three-electrode amperometric system
Monster stroomsnelheid: 30 - 50 L/uur (7.9 - 13.2 gal/uur), Optimaal is 40 L/uur (10.5 gal/uur)
Monster temperatuur: 5 - 45 °C
Montage: Metric
Nauwkeurigheid: Free Chlorine: ± 3 % of the reference test** (DPD) at constant pH less than 7.2 (±0.2 pH unit)
  Free Chlorine: ± of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration)
  Total Chlorine: ± 10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration)
  Total Chlorine: ± 20 % of the reference test** (DPD) at stable pH greater than 8.5
Omgevingstemperatuur: 0 - 45 °C
Omschrijving: CLT10sc Total Chlorine Sensor with Grab Sample (On Panel)
Opslag condities: -20 °C to 60 °C dry
Opties: Panel Only
Parameter: Total Chlorine
pH bereik: 4 - 9 pH
pH Monitoring Required?: None
Responstijd: Free Chlorine: 140 s or less for 90% change (T90)
at a stable temperature and pH
  Total Chlorine: 100 s or less for 90% change (T90)
at a stable temperature and pH
Stroom vereisten (spanning): None
Temperatuur compensatie: Internal temperature compensation in the sensor
  Interne temperatuur compensatie in de sensor
Wat zit er in de doos: CL10sc Panel with Grab Sample, 1 m Digital Extension Cable, Panel Manual, Chlorine Sensor Manual