Polymetron 2586sc Oxygen Scavenger Analyser, Smart Monitoring, Profibus DP, 110-240 VAC, without power cord

Polymetron 2586sc Oxygen Scavenger Analyser, Smart Monitoring, Profibus DP, 110-240 VAC, without power cord
Productnr.: 2586.99.AA2801
Prijs per eenheid Neem contact op
Wordt binnen 2 weken verzonden

Save Time on Design

A single design source and one product platform means you spend less time searching for design files or configuring components.

Easy Adoption

The familiar experience with a modern touchscreen, the ability to use your current Hach sensor, and the same footprint as the 9500 Polymetron, make installation and integration of the SC4500 Controller seamless.

The Connectivity Options You Need

The Controller provides local communication to SCADA or a PLC. From analog, to advanced digital protocols, to wi-fi, cellular or LAN, the SC4500 gives you the flexibility to adapt in a rapidly changing world.

Simplify Maintenance and Operation

Common menu guides reduce variability and provide step-by-step procedures for maintenance and calibration. Standard visual alerts across parameters notify operators when troubleshooting is required. The Hach Polymetron 2586sc has a fast response time of less than 60 seconds.
Unlike traditional amperometric techniques that use two electrodes, the Hach Polymetron 2586sc oxygen scavenger analyser uses a three-electrode design; eliminating voltage drift due to the composition of the water. Self-cleaning electrodes reduce maintenance costs and analyser downtime via PTFE beads that prevent deposits on the electrode surfaces.

Wat zit er in de doos

Controller installed in Panel, Working Electrode, Reference Electrode, Counter Electrode, Basic User Manual

Specificaties

Aansluiting: 4 x 6 mm stainless steel tubing
  6 x 8 mm (tubing must not exceed 4 feet and must drain straight down)
Aantal kanalen: 1
Beveiliging niveau's: 2
Communicatie (facultatief): Analog:
Five 0-20 mA or 4-20 mA analog outputs on each analog output module
Up to two analog Input modules (0-20 mA or 4-20 mA). Each input module replaces a digital sensor input.

Digital:
Profibus DPV1 module
Modbus TCP
Profinet IO module
Ethernet IP module
Communicatie Mogelijkheden: Claros Profibus DP
Detectiegrens: Drift is negligible; 1 ppb
Druk bereik: 0.5 - 6 bar (7.2 - 87 psi) or 12 L/h
Elektrische certificeringen: EMC

CE compliant for conducted and radiated emissions:
- CISPR 11 (Class A limits)
- EMC Immunity EN 61326-1 (Industrial limits)

Safety
CAN/CSA C22.2 No. 61010-1

cETLus safety mark for:
- General Locations per ANSI/UL 61010-1 & CAN/CSA C22.2. No. 61010-1
Flow: 166 - 250 mL/min (10 - 15 L/h) recommended
Gewicht : 14.6 kg
Handleiding talen : Bulgarian, Chinese (PRC), Croatian, Czech, Danish, Dutch, English, Estonian, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Lithuanian, Polish, Portuguese (Brazil), Portuguese (Portugal), Romanian, Russian, Slovak, Slovenian, Spanish, Swedish, Thai, Turkish
Herhaalbaarheid: ± 2% or 1 ppb (whichever is greater)
Materiaal: Counter-Electrode: Stainless steel; Working Electrode: Platinum
Meetbereik: 0 - 100 ppb carbohydrazide (also known as ELIMIN-OX); programmable

ELIMIN-OX is a registered trademark of Nalco Chemical Co., Naperville, IL.
  0 - 500 ppb hydrazine; programmable
  0 - 500 ppb hydrazine; programmable
Monster temperatuur: 5 - 45 °C
Monster voorwaarden: Sample needs to be free of undissolved matter.
Omgevingstemperatuur: 5 - 45 °C at 0 - 95% relative humidity (non-condensing)
Onderhoudsinterval: Monthly: Calibration and reagent refill
Opslag condities: -20 - 70 °C, 0 - 95% relative humidity, non-condensing
Reagens: Sample conditioning with diisopropylamine, ammonia, or diethylamine
Referentie: Ag/AgCl electrode with electrolyte KCl 0.1 M
Relais: Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A
Relais: functioneel: Scheduler (Timer), Alarm, Feeder Control, Event Control, Pulse Width Modulation, Frequency Control, and Warning
Relais: tijdens bedrijf: Primary or secondary measurement or timer/scheduler
Relatieve luchtvochtigheid: 10 - 90% relative humidity (non-condensing)
Responstijd: < 60 s
Software beschikbaar: Cloud (Claros-enabled)
Stroom vereisten (spanning): 110 - 240 V AC
Stroomvoorziening: Without power cord
Wat zit er in de doos: Controller installed in Panel, Working Electrode, Reference Electrode, Counter Electrode, Basic User Manual